Suite 1.3.1 · 9 programs

Easy Tools

Engineering tools for quickly checking a design. Responsibility for the structure stays with the designer — check the results.

The Easy Tools launcher with a tile for each program
🧮Nine programs in one package
🪟Windows, signed installer
🔄Updates straight from the launcher
🔑Per-computer licence, activated once

Why Easy Tools exist

Every engineer ends up building their own helpers — a spreadsheet here, a Mathcad sheet there, a little program only they understand. Easy Tools are exactly that, rebuilt into one package: done properly, and in a way someone other than the author can use. For a small fee, because somebody has to keep working on it. Programs keep being added and the old ones keep improving.

What they are for

For quickly checking a design you already have in your head. In early stages you need to know within minutes whether it works out — not wait for a full model. You start from experience; the tool either confirms it or pulls you up short. Both are useful.

What they are not

They are not assessments and they carry no responsibility for the structure. That is yours. Check the result — the method, the inputs, and whether the question you asked is really the one you meant to ask. If a tool makes sense to you, use it. If not, don't.

When something doesn't add up

Write to us. Whether it is the whole method or a single formula — we will look at it, and if it is a mistake, we will fix it. That is where the value is: a tool that can be corrected is worth more than a tool that has to be trusted.

Write to info@easybridge.sk — the method, the inputs, a single formula, anything that doesn't add up.
The 'How we mean it' window inside the program
The same wording is in the program itself — the “How we mean it” window.

What is in the package

Nine programs

All images are real screenshots of the programs, not mock-ups. The programs compute actions and quantities — they do not compute resistance.

Which standards this follows — please read

The programs are built on European standards (EN — Eurocodes). Some selected calculations, however, follow the technical conditions of a specific country — for example load rating to TP 104 (SK). What holds here does not have to hold across the border.

So for each program below, check what exactly it computes and to which rules. If you are not sure whether it fits your case or another country, write to us and we will tell you straight away.

How the suite works as a whole — installation, versions, licence

One signed installer (BlueberryS s. r. o.), one uninstall entry and one Start-menu group; the programs are components and can be picked during installation. The Easy Tools launcher is always installed — a tile per program with the version of the executable it found, the licence status in the header, and the „How we mean it“ window carrying the same text as the manifesto above. Both the launcher and the modules have a light and a dark theme, and the launcher passes the theme on to the program it starts. The launcher compares the running version against the suite manifest and tells you when a newer one exists — it neither downloads nor runs the installer by itself.

Windows x64. The programs are self-contained, so no separately installed .NET is needed; that is why the installer is large. The version is the version of the suite, not of the program — every program carries the same number even if it did not change between releases. The licence is the Easy Solution package licence (together with Easy CAD, Easy Bridge and Easy Rebar), tied to the computer and activated once; the activation program is part of the installation.

Common to all of them: every program writes a Word report (.docx) in the style of a structural calculation — substituted formulas, references to clauses, and a chapter stating what is not part of this version — and every program has its own input format in readable JSON, so the input is archivable and you can come back to it a year later.

Retaining walls: cross section, longitudinal model and utilisation envelopes

Retaining walls

Manual input or import from EasyBridge, cross sections, expansion units and 3D. Geotechnical checks, utilisation envelopes and a report to Word.

Details for engineers

What it calculates

A prismatic stem, a rectangular base slab, horizontal ground surfaces, one backfill soil and one founding soil, and an optional rectangular heel key; levels are absolute and all effects are per metre run. Active pressure as well as at-rest pressure, two groundwater tables, uplift and surcharge. A new section opens in DA2 + EQU + UPL to STN EN 1997-1 and the Slovak NA:2010: DA2 as A1+M1+R2 (γG 1.35/1.0, γQ 1.5/0, γRv 1.4, γRh 1.1, γRe 1.4), EQU with γtanφ 1.25 and c′ = 0, UPL for uplift. By NA.2.2 and NA.2.4 water carries a factor of 1.0, so groundwater levels are entered as design levels. Sliding, overturning about both edges, uplift and compressive contact are checked with combination envelopes. The bearing resistance is calculated automatically to STN 73 1001:2010, cl. 10 from φ′, c′, the geometry and the water, for every combination. Your own design Rd [kPa] can be entered and is then not divided by γRv again.

Input and output

Manual input through New wall in the detailed section editor, or an import of the longitudinal model from EasyBridge (easybridge.mur.v1, .ebm); the lossless project format is .esm. The longitudinal model carries expansion units, cross sections, a 0.20 m grid, envelopes of the individual checks, a longitudinal and an unrolled 3D view, and isolation of the selected unit. Safety barriers and wind share one editor and a catalogue of 18 types from the supplied technical sheets with a scheme of the kerb, the surfacing, the barrier and the forces. The output is a utilisation envelope along the expansion units and a Word report.

What it does not do

Settlement, overall stability, seepage and piping, seismic actions, accidental design situations and reinforcement design. Neither the anchorage nor the safety barrier itself is checked. For a resultant inclination θ > 30° the bearing resistance has to be verified separately. An unsupported mode, factor or geometry is rejected, not ignored — the program does not make up what it has no basis for.

Noise barriers: longitudinal view, cross section and the input panel

Noise barriers

A noise barrier from the EasyBridge .phs export — wind actions to STN EN 1991-1-4, aerodynamic zones A to D, longitudinal view and cross section, and an export of the edited data back.

Details for engineers

What it calculates

The characteristic pressure on the barrier to STN EN 1991-1-4: the basic wind velocity and the peak velocity pressure qp, the exposure factor ce, the aerodynamic zones A to D to Table 7.9 and cs·cd to Annex B. The extended post model (n1 and δ from the section, the material, the spacing and the mass per unit area of the panels) is optional. The area belonging to a post is half of the left and half of the right span; the strip is divided at the panel boundaries and at the boundaries of the aerodynamic zones, and every part is integrated as a trapezium. Integrating p·dA and r×dF gives the resultant and the moment at the base in the local system of the post.

Input and output

The input is a .phs file from EasyBridge PHS3D; one file may contain several curves and each is treated as a separate continuous barrier. The longitudinal view shows the alignment, the panels with their step-down tops, the posts and the stations, the distribution of wk above the barrier and the bands of the zones below it. The project is saved as .esp, the calculation data can be exported back into a copy of the original .phs (only the calculation block is written) and a single post separately as .phsd. A post whose identity or geometry fingerprint does not match is not written and the reason is reported.

What it does not do

It does not calculate resistance. The output is characteristic values without γ and ψ; the design of the post, of its anchorage and of the foundation is outside the program. It does not change the drawn geometry — dimensions are changed in PHS3D. The zone diagram A/B/C/D is drawn only for a barrier of constant height; for a varying height the program gives a constant conservative envelope and labels it as such. The model is a straight vertical wall along the arc length, so a strongly curved barrier needs a separate model. A free gap under a panel is rejected. The bottom of a panel is taken down to the alignment of the curve — undercasting, the pile cap and the kerb are not deducted.

EasyStatics: the list of recent models with previews

EasyStatics

A preliminary structural check of a bridge at the design-intent stage — it opens the EasyBridge export, computes the forces into the piers and piles, and writes a report.

Details for engineers

What it is for

The new Slovak building act replaced the former design stages with the design intent and the construction project. At the design-intent stage a quasi-structural check is required, but there is neither the time nor the fee for a full calculation. EasyBridge can enter a large bridge in minutes — and this export yields the forces into the piers and piles, so the engineer forms a picture in hours, not weeks. The aim is to verify that the structure is realistic, not to design it; the main output is the kg/m³ ratio you compare against experience. The acceptance criterion is not in the program.

The model

A plane frame in X–Z, linear, all nodes in one plane. The solver is BriefFiniteElement.NET behind an IEsRiesic interface, so it can be swapped. A section is entered as a polygon and A, Iy and the extreme fibre positions are obtained by Green's theorem — a polygon flagged as a void is subtracted, so a voided slab is entered directly instead of as a guessed equivalent stiffness. A tandem travelling along a path gives a max/min envelope; the chequerboard pattern is solved case per span and enveloped by sign. The LM1 generator sets out notional lanes to EN 1991-2, Table 4.1; the LM71 generator 4×250·α + 80·α with Φ2/Φ3. The whole path downwards is covered: reaction → bearings → foundation base → force in a pile.

Checks

A check sits behind the IEsPosudok interface — it receives sections and forces, returns utilisations, and sees neither the model nor the solver. Built in: SLS concrete stresses (0.60 / 0.45 fck), ULS bending resistance (EN 1992-1-1, cl. 6.1), shear (6.2.2, 6.2.3, 9.2.2), crack width (7.3.2 and 7.3.4), bending reinforcement of a beam (9.2.1.1), pier reinforcement (9.5.2). A foreign check can be attached as a separate program in any language. The host enforces two rules: a check that does not state its method is not loaded, and a failed check is never passed off as satisfactory.

Load rating (TP 104/2024)

The Load rating tab computes partial load ratings of the superstructure from the geometry of the current model, the actual reinforcement and bonded prestressing: ULS bending with axial force N–M and shear V, SLS stresses, cracking and decompression according to the type of structure and the environment → Vn/Va/Vi/Ve, a CSV file and a report chapter. Where the shear legs cannot be assigned reliably, the program blocks the numerical summary and states why.

What it does not do

There is no transverse direction — transverse distribution between beams, torsion and local slab effects are not determined by this model; that is not a missing feature, it is a decision about what the tool is. There is no second-order analysis: internal forces are computed on the undeformed structure. Crowd loading on a footbridge and the transverse distribution on precast beams are entered by hand. The resulting overall load rating of the bridge to TP 104 is not covered — the program gives the partial values. And none of it is a code assessment.

Rating curve: the start screen with recent projects

Rating curve

The rating curve of a channel — the cross section drawn by hand, discharge by Manning, hydraulic quantities, a check against design discharges and a report to Word.

Details for engineers

What it calculates

Discharge by Manning's equation for a given water level, and with it the hydraulic quantities: flow area S, wetted perimeter O, surface width B, hydraulic radius R, velocity v, the Froude number Fr and the weighted roughness n. Roughness is weighted either by the wetted length or by the Horton–Einstein method; the catalogue includes the Pavlovsky classes I–XV. The inverse task — the water level for a given discharge — is found numerically, so a list of design discharges (Q5, Q100) gives the levels directly and compares them with the soffit of the superstructure. The project type is either the permanent state or the construction state, where the water flows through pipes only.

Input and output

The section is drawn in an editor with zoom, a grid and snapping; the points can also be typed into a table (X, Z, material). The superstructure is a polyline above the channel. The project file is .hydrV and older files are read. Output: the rating-curve plot, the table of quantities, the check against design discharges and a Word report.

What it does not do

Manning assumes uniform steady flow in one section — the water surface profile along the stream, backwater upstream of a bridge, the transition through critical depth and unsteady phenomena are not solved here; Fr is an indicator of that, not a calculation. Sediment transport, scour and silting are not in the program.

Cracking: variants in a table with live recalculation

Cracking

Minimum reinforcement for crack control under shrinkage and restrained actions (EN 1992-1-1 7.3, thick members EN 1992-3 / CIRIA C660).

Details for engineers

What it calculates

Reinforcement for crack control under restrained (imposed) deformations — shrinkage, heat of hydration and restraint, not loading. As,min to EN 1992-1-1, cl. 7.3.2, eq. (7.1) with kc, k, fct,eff and Act, the check against Table 7.2N and the direct crack-width calculation to cl. 7.3.4, and for thick members the surface zone to EN 1992-3 / CIRIA C660. Member types: a wall restrained by its base, a ground-bearing slab and a suspended slab. For a wall the choice of restrained pour ends changes Lef/H and therefore the height of the fully reinforced zone above the base, not the area of reinforcement itself.

How it is entered

As many variants at once as you like, recalculated live, with the columns in the order in which the decision is actually made: you enter the spacing s and get As,min, the bar diameter ø to 7.3.2, the answer to whether wk is satisfied with it, and the diameter that at the same spacing satisfies the crack width as well. When nothing works at that spacing, the column says what will help. The output is Word for the structural calculation: a summary table of the variants and a chapter per variant with substituted formulas. Slovak and English.

What it does not do

Cracking under load (that is a section check, a different task) — and it does not mix the two. It performs no thermal or moisture analysis and no time-dependent hydration: the restraint factor R and fct,eff are inputs, not the result of a simulation. It does not design the layout of construction joints or the casting sequence — the choice of pour ends is an input about what is planned.

Road bridge actions: input and the results of the individual actions

Road bridge actions

Characteristic values of bridge actions — traffic, pedestrians, braking forces, wind and temperature to STN EN 1991-2 and the NA. It replaces the in-house spreadsheet and gives you a chapter for the structural calculation.

Details for engineers

What it calculates

A calculator of characteristic values that you use even when the model itself runs elsewhere — it is not a load generator for an FE model. Eighteen report chapters cover: the adjustment factors α by road category, notional lanes and load models LM1 to LM4 (STN EN 1991-2, Table 4.1), pedestrians, load groups gr1a to gr5, horizontal forces, load spread, accidental design situations (cl. 4.7.3), temperature to STN EN 1991-1-5, earth pressures on the abutments to STN EN 1997-1, permanent actions, the back wall including its reinforcement, wind on the deck and wind on the pier to STN EN 1991-1-4, and the combination factors γ and ψ to STN EN 1990/A1. Where the national annex says something different from the base standard, the NA governs and the report says so.

Input and output

Its own input file .esz (readable JSON); a new input starts from a sample bridge. The output is Word in the style of a structural calculation with substituted formulas and clause references — it can be attached as a chapter — plus the chapter on what is not part of this version. Verification: seven inputs and 569 checks in the regression set, 82 values compared against individual cells of a reference calculation of a real job.

What it does not do

Seismic actions (that is the Response spectrum program), prestressing, creep and shrinkage, the dynamic response to wind, fatigue loading, the self-weight of the superstructure and the pressure from the tandem on the abutment to the old STN 73 0037. It gives characteristic values — γ and ψ are tabulated in the report, but the combinations are assembled by the engineer in their own model.

Railway bridge actions: load models and horizontal forces

Railway bridge actions

Actions from rail traffic — load models LM71 and SW/2, the dynamic factor, centrifugal and longitudinal forces and wind to STN EN 1991-2; both the Slovak and the Czech standard.

Details for engineers

What it calculates

Nine sections to STN EN 1991-2, Section 6: the input data and the table of the dynamic factor (Φ2 for ULS/SLS, Φ3 including its lower bound), the vertical models LM71 and SW/0, SW/2, the unloaded train at 10 kN/m, the centrifugal force, the nosing force, traction and braking, the load groups gr11 to gr17 to Table 6.11, the load spread through the fill (ballast 4:1, soil at the angle φ) and the transverse distribution with eccentricity. Wind comes with a wind map — for Slovakia Figure NB 1, for the Czech Republic a table of zones I–V.

Country means standard, not language

The country switch changes the classification factors α, the lower bound of Φ3 and the wind zones — that is, the numbers. The language switch (SK/CZ/EN) changes the text only, so an English report can follow the Slovak or the Czech standard. The translation coverage is not an estimate: a test fails as soon as a term is missing in one of the languages.

Input and output

The input file is .eszz (readable JSON) and files of the original in-house tool are read as well; work in progress is saved continuously. Output: a Word .docx and paginated printing. Verification: seven inputs, 666 checks and 59 language tests; this is a conversion of a tool used in practice and the content of the calculation was not changed in the process.

What it does not do

One track — two tracks are not a setting but a new feature. It performs no dynamic analysis to cl. 6.4.6 (resonance, speeds above 200 km/h), no fatigue and no track–structure interaction. The output is characteristic values without γ and ψ.

Reinforcement cover: the cover schedule and the anchorage lengths tab

Reinforcement cover

Cover to reinforcing and prestressing steel to STN EN 1992-1-1, cl. 4.4.1 — exposure classes, allowances — plus anchorage and lap lengths (cl. 8.4 and 8.7). It replaces three spreadsheets.

Details for engineers

What it calculates

The first tab: cover to STN EN 1992-1-1, cl. 4.4.1 — cnom = cmin + Δcdev, where cmin is the maximum of the bond requirement and the durability requirement (Table 4.4N for reinforcing and Table 4.5N for prestressing steel), with exposure classes XC/XD/XS/XF/XA, the structural class from the design working life of 50/80/100 years and the class modifications of the national annex. Allowances to cl. 4.4.1.2(11) and (13). The second tab: anchorage and lap lengths to cl. 8.4 and 8.7 — fbd, lb,rqd, lbd in tension and in compression, the lap length l0 with the factors α1–α6.

Input and output

The input file is .esk. The main output is the cover schedule — cmin and cnom for every structural element in one table, ready to be written onto the drawings. The numerical tables live in the code as data with a reference to the page of the standard, and the regression test refers to the page of the standard, not to the original spreadsheet. The calculation core is also delivered as a library for Easy Rebar, so the anchorage lengths on the drawing and in this program come from the same code.

What it does not do

It does not design the reinforcement and does not check the section — it calculates cover and lengths from what you enter. Durability itself is not modelled: the exposure class is an input. The anchorage tab covers reinforcing steel and straight bars without hooks only; mechanical anchorage, loops, welded transverse bars and the factors for prestressing steel are not in it. It does not check whether the anchorage fits into the member — it gives a length, not a check of the geometry.

Response spectrum: the Se(T) plot and the parameters of the ground type

Response spectrum

Elastic and design response spectra to STN EN 1998-1 and STN 73 0036 — horizontal and vertical, ground type, damping and the behaviour factor.

Details for engineers

What it calculates

Three spectra: the horizontal elastic spectrum Se(T) to STN EN 1998-1, cl. 3.2.2.2, the horizontal design spectrum Sd(T) to cl. 3.2.2.5 with the lower bound β·ag, and the vertical elastic spectrum Sve(T). ag = agR·γI, η = √(10/(5+ξ)) ≥ 0.55; η does not enter the design spectrum, where q takes its role. There are two sets of ground parameters and the report always states which was used: the Slovak national annex (Table NB.5.1), or the EN recommended values (Tables 3.2 and 3.3), which differ from the NA. From ag·S the program classifies the seismicity — for bridges this is often the single most important number, because it says whether seismic design has to be done at all.

Input and output

The input file is .ess. Output: the Se(T) plot in which the breaks of the curve are exact points (not an artefact of sampling), a table of values at a uniform step for pasting into an analysis program, the substituted calculation, the classification and a Word report; the plot in the window and the plot in the report come from the same code. Fourteen regression inputs, all verified by mutation.

What it does not do

It does not derive q — for bridges it is given by EN 1998-2 and depends on the type, the slenderness and the reinforcement of the pier, so it is entered by hand and the report says so explicitly. β defaults to 0.20; the binding value is the one in the national annex. It does not combine the components, and it does not deal with modal analysis, masses or the natural frequencies of the structure — it gives the input for a model, not the response of a structure.

How do I get it

Download and activation

One installer for the whole suite. The launcher checks for updates by itself, so new programs and fixes arrive without another download.

Download EasyToolsWebSetup.exe
Suite version 1.3.1 · Windows · the installer is signed

In the Easy Solution package

Easy Tools are part of the Easy Solution package together with Easy CAD, Easy Bridge and Easy Rebar — the whole suite, all nine programs and the ones still to come. See package pricing.

A standalone licence

In preparation. For now Easy Tools can only be bought as part of the Easy Solution package. Write to us if that does not work for you.

Activation

The licence is tied to the computer and is activated once. After that the programs start without asking.

Something doesn't add up? Write — we will look at it.