Retaining walls
Manual input or import from EasyBridge, cross sections, expansion units and 3D. Geotechnical checks, utilisation envelopes and a report to Word.
Details for engineers
What it calculates
A prismatic stem, a rectangular base slab, horizontal ground surfaces, one backfill soil and one founding soil, and an optional rectangular heel key; levels are absolute and all effects are per metre run. Active pressure as well as at-rest pressure, two groundwater tables, uplift and surcharge. A new section opens in DA2 + EQU + UPL to STN EN 1997-1 and the Slovak NA:2010: DA2 as A1+M1+R2 (γG 1.35/1.0, γQ 1.5/0, γRv 1.4, γRh 1.1, γRe 1.4), EQU with γtanφ 1.25 and c′ = 0, UPL for uplift. By NA.2.2 and NA.2.4 water carries a factor of 1.0, so groundwater levels are entered as design levels. Sliding, overturning about both edges, uplift and compressive contact are checked with combination envelopes. The bearing resistance is calculated automatically to STN 73 1001:2010, cl. 10 from φ′, c′, the geometry and the water, for every combination. Your own design Rd [kPa] can be entered and is then not divided by γRv again.
Input and output
Manual input through New wall in the detailed section editor, or an import of the longitudinal model from EasyBridge (easybridge.mur.v1, .ebm); the lossless project format is .esm. The longitudinal model carries expansion units, cross sections, a 0.20 m grid, envelopes of the individual checks, a longitudinal and an unrolled 3D view, and isolation of the selected unit. Safety barriers and wind share one editor and a catalogue of 18 types from the supplied technical sheets with a scheme of the kerb, the surfacing, the barrier and the forces. The output is a utilisation envelope along the expansion units and a Word report.
What it does not do
Settlement, overall stability, seepage and piping, seismic actions, accidental design situations and reinforcement design. Neither the anchorage nor the safety barrier itself is checked. For a resultant inclination θ > 30° the bearing resistance has to be verified separately. An unsupported mode, factor or geometry is rejected, not ignored — the program does not make up what it has no basis for.